Nuaire Hitachi Koki himac CS150NX Tabletop Micro Ultracentrifuge
Features
Technologies
- Reliable Drive Unit
The CS150NX only takes 90 seconds to reach the world's fastest speed 150,000rpm by himac original vacuumed drive unit. The Drive Unit is backed by a 5 Year Warranty.
- Imbalance Protection System
Samples need to be balanced within 5mm by visual check only. A non-contact imbalance sensor monitors vibration of the rotor and drive shaft. In the event of unexpected vibrations the Imbalance Protection System activates and ceases operation immediately.
- Self-Locking Rotor System
Installing and removing a rotor has never been simpler. Place the rotor on the drive shaft and thats it. The rotor is automatically locked by centrifugal force. There is no need for screws, tools, or buttons.
- Self-Locking Rotor System
With the use of only your hands, rotors may be placed and remove from the drive shaft. Centrifugal force locks the rotor into position without the use of tools.
- Simplified Operation with Touch Screen Controls
A color touch screen LCD with graphic user interface simplifies user operation by using universal icons. High contrast text and buttons on a black color background makes user system recognition easy.
- Quiet Operation of 45 dbA
Just louder than a whisper, the CS150NX can attribute its quiet operation to rigid-control drive system and sound absorbing structure design.
- Easy Timer Setting and Actual Run Timer
The himac original RTC (real-time control) function makes timer setting easy. Simply set the start time or finish time along with running time. It is easier than conventional delay time setting timer.
The himac original Actual Run Timer starts when the setpoint speed is attained and excludes acceleration time from the set time. It helps to precisely control the net run-time and obtain high-reproducibility separation. Of course, conventional run timer is selectable.
- User Administration with Password Protection
Control users by regiserting them to the system with different access levels and passwords.
Options
- Biosafety Option
In order to prevent from exhausting bio-hazardous samples into the laboratory, a micro-filter can be assembled in a vaccum line as an option.
Specifications
Model | CS150NX |
Maximum Speed (rpm) | 150,000 |
Maximum RCF (xg) | 1,050,000 (S140AT rotor) |
Speed Control Accruacy (rpm) | ±50 (5,000 to max speed) |
Maximum Capacity (nominal) | 30ml x 6 tubes (S50A rotor) |
Maximum Capacity (nominal) (Swinging Bucket Rotor) | 7ml x 4 tubes (S50ST rotor) |
Timer | 1 min. to 99 hrs. and 59 min. with HOLD and RTC (real-time control) function |
Vaccum System | Oil rotary vaccum pump and oil diffusion pump |
Rotor Temperature Control Range (°C) | 0 to +40 (1 degree increment) |
Rotor Cooling Method | Thermo-module Cooling System (HFC free) |
Screen Display | Color LCD (touch-sensitive) |
Rotor Setting Method | Self-locking Rotor System (no tools required) |
Operational Noise (dbA*) | 45 *Measured 1 meter from front of unit |
Maximum Heat Dissipation into Room (kW) | 0.7 or Less |
Exertior Dimensions (W x D x H) | 23 ¼ x 22 ¾ x 16 ¼ in. (590 x 582 x 408 mm) |
Floor Area | 5½ ft² (33 ½ x 23¼ in.) [0.50 m² (850 x 590 mm) |
Weight | 214 lbs. (97 kg) |
Power Requirements |
AC 110 or 120V ±10%, 15A (50/60 Hz), Single Phase AC 208, 220, 230, 240 V ±10%, 8A (50/60 Hz), Single Phase |
Drive Unit Warranty | 5 Years |