Planer Kryo 360 Controlled Rate Freezer

PDFPrintEmail
The Kryo 360 is a medium capacity Controlled Rate Freezer is used for pre freezing specimens before liquid nitrogen storage in applications.
Request Quote
Download Brochure

Planer Kryo 360 Controlled Rate Freezer

Description

The Kryo 360 Controlled Rate Freezer is used for pre freezing specimens before liquid nitrogen storage in applications such as:

  • In Vitro Fertilization - human and animal
  • Assisted Reproduction
  • Ovarian Tissue freezing
  • Embryo, Sperm and Oocyte freezing
  • Animal husbandry
  • Tissue preservation
  • Cell line freezing

The Kryo 360 is a medium capacity controlled rate freezer: ideal for an IVF, ART or research laboratories.

Menu driven with fast cooling rates, controlled heating and multiple safety features.

Repeatability, consistent results and data recording are available from this reliable system used to freeze biological samples prior to long term cryo storage.

The equipment has multiple safety features, has data printing via its integral printer and allows multiple protocols. Controlled freezers give consistent results with validated high post thaw viability.

Also available in a non Medical Device version

Benefits:

  • Simple to use through easy menus
  • Safety records: ‘Run’ print out available
  • User can define Horizontal or Vertical freezing
  • Warming ramps are controlled
  • Recording assists validation processes
  • User changeable protocols allow technique updates
  • PC failure accommodated – when running with software
  • The -180ºC end temperature helps sample integrity during transfers

Features

Controlled heating

Chamber volume: 1.7 or 3.3 litres

Copes with temporary power/system outs

Lower temperature limit: -180 ºC

User calibration with hard copy

Cooling rates: -0.01 to -50 ºC/min

PC connection compatible

Controlled heating rates: 0.01 to 10 ºC/min

Time and date stamping

System controller: Planer's MRV controller

Programme preview before run

DeltaT Lite Software (Upgrades: V6/V7)

Control and data systems separated

Data storage and run are independent

Straw capacity: 60 x 0.25 ml or 45 x0.5ml

Vial or ampoule capacity: (30 or 60) x 2 ml

Straws in 15 positions radially located

Vials in 15 positions radially located

Specifications

System Specifications
Range +40°C to -180°C
Heating rate 0.01°C/min to 10°C/min
Cooling rate -0.01°C/min to -50°C/min
Controller accuracy ±0.3 °C measured on a hold at 0 °C
Storage temperature -10°C to +50°C
Storage humidity 5% to 95% relative humidity non-condensing
Operating temperature 5°C to 40°C
Operating humidity 5% to 90% relative humidity non-condensing
Controller Specifications
Dimensions 80mm high x 220mm wide x 350mm deep
Weight (approx.) 2.6 kg
Display 240 x 64 LCD with CCFL backlight
Printer 320/640 dot thermal printer
Keypad 20 key membrane keypad
Programmable Cooling Rate Range -0.01°C/min to -99.9°C/min
Number of profiles 10
Steps per profile 32
Number of stored runs 10
Chamber Specifications
Weight (kg) 14.4kg (1.7 Liter) or 14.7kg (3.3 Liter)
Chamber dimensions 1.7 L chamber:
  Internal 200mm x 150mm diameter External 450mm high x 300
mm wide x 420mm deep 3.3 L chamber: Internal 400mm x 150
mm diameter External 450mm high x 300mm wide x 420mm deep
0.25 ml straws 60 (1.7 L and 3.3 L chamber)
0.5 ml straws 45 (1.7 L and 3.3 L chamber)
2 ml vials 30 (1.7 L chamber) or 60 (3.3 L chamber)
Power requirements (including MRV Controller) 115V~ 50/60Hz 600VA / 230V~ 50/60Hz 600VA
Additional Equipment Recommendation
5 psi System System Pump - LNP4-C
  System Dewar - MVLAB 30
22 psi System System Cylinder - MVEUROCYL230SB
  Phase Separator - MVPHASE
22 psi System (alternative) Vacuum Jacketed Pipe Work System
  Phase Separator - MVPHASE